Ademco Contact ID (SIA DC-05)

Contact ID is the most widely supported DTMF digital dialer format. Each message carries an account number, an event qualifier (new event or restore), a three-digit event code, a partition and a zone or user number.

Origin

Where Contact ID comes from

Introduced by Ademco and later standardized by SIA as DC-05.

How it works

Technical details

  • Sent as DTMF tones over a telephone-style connection, so it is sensitive to the audio quality of VoIP and digital phone lines.
  • Event codes are standardized (for example 1xx alarms, 3xx troubles, 4xx open/close), which makes it easy for a central station to automate.
  • Supported by most universal cellular communicators that capture the dialer output and forward the event over LTE or IP.

Upgrades

Replacing the phone line

  • If a panel already reports Contact ID, a universal cellular dialer capture or a manufacturer-native communicator is usually the simplest phone-line replacement.
  • We test every zone and trouble condition after the change, because a capture device can mask dialer-timing issues that only appear on specific events.

Panels

Panels commonly documented with Contact ID

If a panel reports through a separate communicator, its actual format depends on that equipment.

VISTA-20PAdemco / Honeywell VISTAVISTA-15PAdemco / Honeywell VISTAVISTA-10PAdemco / Honeywell VISTAVISTA-21iPAdemco / Honeywell VISTAVISTA-128BP / 128BPTAdemco / Honeywell VISTAVISTA-250BP / 250BPTAdemco / Honeywell VISTAVISTA-128FBP / 250FBPAdemco / Honeywell VISTAVISTA-50P / VISTA-100Ademco / Honeywell VISTAMagnum Alert seriesNAPCO Magnum and GeminiGemini GEM-P816NAPCO Magnum and GeminiGemini GEM-P1632NAPCO Magnum and GeminiGemini GEM-P3200NAPCO Magnum and GeminiGemini GEM-P9600NAPCO Magnum and GeminiPowerSeries PC1832DSC PowerSeries and MAXSYSPowerSeries PC1864DSC PowerSeries and MAXSYSPowerSeries PC1616DSC PowerSeries and MAXSYSPC1555 / Power832 PC5010 / PC585DSC PowerSeries and MAXSYSMAXSYS PC4020DSC PowerSeries and MAXSYSXL-2FBII (FBI) XLXL-4FBII (FBI) XLXL-31FBII (FBI) XLNX-8Caddx / GE / Interlogix NetworXNX-8ECaddx / GE / Interlogix NetworXNX-4 / NX-6Caddx / GE / Interlogix NetworXZ1100 seriesMoose SecurityZ900Moose SecurityMS-9200UD / MS-9200UDLSFire-LiteMS-9600UDLSFire-LiteMS-5024 / MS-5210UDFire-LiteMS-10UD / MS-25UDFire-LiteAFP-200NotifierAFP-300 / AFP-400NotifierAFP-1010 / AM2020NotifierNFS-320 / NFS-640Notifier4100 / 4100USimplex4100ESSimplex4020Simplex4010 / 4002SimplexEST3Edwards / ESTEST2Edwards / ESTQuickStart QS1 / QS4Edwards / ESTIRC-3Edwards / ESTXR2400FDMP (Digital Monitoring Products)XR500 / XR500NDMP (Digital Monitoring Products)XR100 / XR200DMP (Digital Monitoring Products)XR40 / XR20DMP (Digital Monitoring Products)D9412GV2 / GV3 / GV4Radionics / BoschD9412GRadionics / BoschD7412G / D7412GV2+Radionics / BoschSK-5820XLSilent KnightSK-5700Silent KnightSK-5207 / SK-5208Silent KnightSK-6808 / SK-6820Silent Knight

FAQ

Contact ID questions

Does Contact ID work over VoIP?

Sometimes, but not reliably. VoIP compression can distort DTMF tones and cause failed or partial reports. Moving to a cellular or IP communicator removes that risk.

Can a fire alarm panel send Contact ID?

Yes. Many fire alarm control panels with built-in DACTs support Contact ID. The monitoring path still has to meet the code and the AHJ's requirements for that building.

Model and format information comes from manufacturer documentation and field experience. Panel revisions, firmware, programming and attached communicators change what a specific system can do, so Fireside confirms every system on site before quoting. Fire alarm monitoring changes must meet NFPA 72 and local fire authority requirements.