DMP (Digital Monitoring Products) · Fire

XR2400F monitoring & upgrades

The DMP XR2400F is an older commercial fire panel in the XR family.

At a glance

Panel details

Manufacturer
DMP (Digital Monitoring Products)
Model
XR2400F
Family
XR fire
Panel type
Fire
Communicator
Built-in dialer with DMP DD and other formats depending on firmware. Fire use needs a listed path.
Documented formats
DMP DDContact ID

Technical notes

What to know about the XR2400F

  • Firmware revision decides which network or cellular options are available.
  • Fire monitoring path must meet NFPA 72 and local fire authority requirements.

Why customers call

Common reasons for a monitoring upgrade

  • Copper line retirement
  • Fire marshal findings

Phone lines

Telephone line replacement

  • The XR2400F's built-in dialer expects a phone line. When the carrier removes copper or moves the line to VoIP, signals can be delayed, partial or lost.
  • We test signals to the central station before and after the change, so you have a record that every alarm, trouble and supervisory signal arrives.
  • For fire alarm monitoring, the replacement path must meet NFPA 72 and the local fire authority's requirements. Some jurisdictions require a permit or acceptance test.

Cellular & IP

Monitoring options

  • Commonly documented formats for this model include DMP DD, Contact ID. The format actually in use depends on programming, firmware and any attached communicator.
  • Because this panel may use a manufacturer-specific format, we usually prefer a manufacturer-compatible cellular or network path, or reprogramming to a format the new communicator supports.
  • For fire signals, we use communicators listed for fire alarm service and dual-path (cellular plus IP) options where appropriate.

Takeover

Commercial monitoring takeover

  • We inspect the XR2400F, confirm programming access and back up the existing settings where possible.
  • We move the account to Fireside's UL-Listed central station and set up your call list and dispatch instructions.
  • Every zone and trouble signal is tested end to end before we close out the job.

See fire alarm system takeover.

Fire alarm

Fire alarm monitoring

  • Alarm, supervisory and trouble signals are monitored 24/7 by a UL-Listed central station.
  • Replacement communicators are listed for fire alarm service and installed to meet NFPA 72 and local fire authority requirements.
  • We can also handle annual inspection and testing for the same system.

Learn more about commercial fire alarm monitoring.

FAQ

XR2400F questions

Can Fireside monitor my DMP (Digital Monitoring Products) XR2400F?

In most cases, yes. We check the XR2400F's condition, programming access and reporting format on site, then recommend whether to keep it with a new communicator or replace it.

What happens to my XR2400F when the phone line is removed?

Its built-in dialer can't reach the central station, so signals stop or become unreliable. A cellular or IP communicator restores reporting.

What format does the XR2400F report in?

Commonly documented options are DMP DD, Contact ID. The actual format depends on programming and any attached communicator, so we confirm it on site.

Related

Other DMP (Digital Monitoring Products) panels

Model and format information comes from manufacturer documentation and field experience. Panel revisions, firmware, programming and attached communicators change what a specific system can do, so Fireside confirms every system on site before quoting. Fire alarm monitoring changes must meet NFPA 72 and local fire authority requirements.