San Francisco Pillow Test (SFFC 1103.7.6.1) — 75 dBA at every pillow. Deadline passed; fines are being issued.

Get compliant →

DSC PowerSeries and MAXSYS · Intrusion

PC1555 / Power832 PC5010 / PC585 monitoring & upgrades

The PC1555, Power832 (PC5010) and PC585 are earlier DSC panels that came before the current PowerSeries. Many are still installed in older commercial buildings.

At a glance

Panel details

Manufacturer
DSC PowerSeries and MAXSYS
Model
PC1555 / Power832 PC5010 / PC585
Family
Older PowerSeries
Panel type
Intrusion
Communicator
Built-in dialer. Communicator compatibility is more limited on these older boards.
Documented formats
Contact IDSIAPulse formats

Technical notes

What to know about the PC1555 / Power832 PC5010 / PC585

  • Older boards can have trouble with newer communicators. We test before committing to keep the panel.
  • Keypads and expanders are mostly available only as used or refurbished parts.

Why customers call

Common reasons for a monitoring upgrade

  • Aging panel
  • Phone line removal
  • Planning a replacement

Phone lines

Telephone line replacement

  • The PC1555 / Power832 PC5010 / PC585's built-in dialer expects a phone line. When the carrier removes copper or moves the line to VoIP, signals can be delayed, partial or lost.
  • We test signals to the central station before and after the change, so you have a record that every alarm, trouble and supervisory signal arrives.

Cellular & IP

Monitoring options

  • Commonly documented formats for this model include Contact ID, SIA, Pulse formats. The format actually in use depends on programming, firmware and any attached communicator.
  • A universal cellular communicator that captures the dialer, or a manufacturer-native cellular/IP module, is usually the simplest option.
  • For intrusion, cellular with IP backup keeps alarms flowing if one path goes down.

Takeover

Commercial monitoring takeover

  • We inspect the PC1555 / Power832 PC5010 / PC585, confirm programming access and back up the existing settings where possible.
  • We move the account to Fireside's UL-Listed central station and set up your call list and dispatch instructions.
  • Every zone and trouble signal is tested end to end before we close out the job.

See commercial intrusion monitoring.

FAQ

PC1555 / Power832 PC5010 / PC585 questions

Can Fireside monitor my DSC PowerSeries and MAXSYS PC1555 / Power832 PC5010 / PC585?

In most cases, yes. We check the PC1555 / Power832 PC5010 / PC585's condition, programming access and reporting format on site, then recommend whether to keep it with a new communicator or replace it.

What happens to my PC1555 / Power832 PC5010 / PC585 when the phone line is removed?

Its built-in dialer can't reach the central station, so signals stop or become unreliable. A cellular or IP communicator restores reporting.

What format does the PC1555 / Power832 PC5010 / PC585 report in?

Commonly documented options are Contact ID, SIA, Pulse formats. The actual format depends on programming and any attached communicator, so we confirm it on site.

Related

Other DSC PowerSeries and MAXSYS panels

Model and format information comes from manufacturer documentation and field experience. Panel revisions, firmware, programming and attached communicators change what a specific system can do, so Fireside confirms every system on site before quoting. Fire alarm monitoring changes must meet NFPA 72 and local fire authority requirements.