Notifier · Fire
AFP-300 / AFP-400 monitoring & upgrades
The AFP-300 and AFP-400 are Notifier addressable panels common in schools, offices and medical buildings from the 1990s and 2000s.
At a glance
Panel details
- Manufacturer
- Notifier
- Model
- AFP-300 / AFP-400
- Family
- AFP
- Panel type
- Fire
- Communicator
- Reports through a separate communicator (commonly a UDACT). The format depends on that equipment.
- Documented formats
- Contact IDSIAPulse formats
Technical notes
What to know about the AFP-300 / AFP-400
- Zone or point reporting depends on how the UDACT was set up.
- The panel's network and annunciator setup should be documented before changes.
Why customers call
Common reasons for a monitoring upgrade
- Copper line retirement
- UDACT failure
- Takeover
Phone lines
Telephone line replacement
- The AFP-300 / AFP-400 usually reports through a separate communicator, so the phone-line replacement is planned around that device, not the panel.
- We test signals to the central station before and after the change, so you have a record that every alarm, trouble and supervisory signal arrives.
- For fire alarm monitoring, the replacement path must meet NFPA 72 and the local fire authority's requirements. Some jurisdictions require a permit or acceptance test.
Cellular & IP
Monitoring options
- Commonly documented formats for this model include Contact ID, SIA, Pulse formats. The format actually in use depends on programming, firmware and any attached communicator.
- A universal cellular communicator that captures the dialer, or a manufacturer-native cellular/IP module, is usually the simplest option.
- For fire signals, we use communicators listed for fire alarm service and dual-path (cellular plus IP) options where appropriate.
Takeover
Commercial monitoring takeover
- We inspect the AFP-300 / AFP-400, confirm programming access and back up the existing settings where possible.
- We move the account to Fireside's UL-Listed central station and set up your call list and dispatch instructions.
- Every zone and trouble signal is tested end to end before we close out the job.
Fire alarm
Fire alarm monitoring
- Alarm, supervisory and trouble signals are monitored 24/7 by a UL-Listed central station.
- Replacement communicators are listed for fire alarm service and installed to meet NFPA 72 and local fire authority requirements.
- We can also handle annual inspection and testing for the same system.
Learn more about commercial fire alarm monitoring.
FAQ
AFP-300 / AFP-400 questions
Can Fireside monitor my Notifier AFP-300 / AFP-400?
In most cases, yes. We check the AFP-300 / AFP-400's condition, programming access and reporting format on site, then recommend whether to keep it with a new communicator or replace it.
What happens to my AFP-300 / AFP-400 when the phone line is removed?
The separate communicator that reports for the panel loses its line. We replace or reprogram that communicator to use cellular or IP.
What format does the AFP-300 / AFP-400 report in?
Commonly documented options are Contact ID, SIA, Pulse formats. The actual format depends on programming and any attached communicator, so we confirm it on site.
Model and format information comes from manufacturer documentation and field experience. Panel revisions, firmware, programming and attached communicators change what a specific system can do, so Fireside confirms every system on site before quoting. Fire alarm monitoring changes must meet NFPA 72 and local fire authority requirements.