Edwards / EST · Fire
EST2 monitoring & upgrades
EST2 is a mid-size Edwards addressable panel that came before the iO series.
At a glance
Panel details
- Manufacturer
- Edwards / EST
- Model
- EST2
- Family
- EST2
- Panel type
- Fire
- Communicator
- Reporting depends on the installed dialer or communicator.
- Documented formats
- Contact IDSIA
Technical notes
What to know about the EST2
- Parts availability is declining. We check the panel's condition.
Why customers call
Common reasons for a monitoring upgrade
- Copper line retirement
- Planning a replacement
Phone lines
Telephone line replacement
- How the EST2 reports depends on the installed communicator module or separate device. We confirm it on site before planning the replacement.
- We test signals to the central station before and after the change, so you have a record that every alarm, trouble and supervisory signal arrives.
- For fire alarm monitoring, the replacement path must meet NFPA 72 and the local fire authority's requirements. Some jurisdictions require a permit or acceptance test.
Cellular & IP
Monitoring options
- Commonly documented formats for this model include Contact ID, SIA. The format actually in use depends on programming, firmware and any attached communicator.
- A universal cellular communicator that captures the dialer, or a manufacturer-native cellular/IP module, is usually the simplest option.
- For fire signals, we use communicators listed for fire alarm service and dual-path (cellular plus IP) options where appropriate.
Takeover
Commercial monitoring takeover
- We inspect the EST2, confirm programming access and back up the existing settings where possible.
- We move the account to Fireside's UL-Listed central station and set up your call list and dispatch instructions.
- Every zone and trouble signal is tested end to end before we close out the job.
Fire alarm
Fire alarm monitoring
- Alarm, supervisory and trouble signals are monitored 24/7 by a UL-Listed central station.
- Replacement communicators are listed for fire alarm service and installed to meet NFPA 72 and local fire authority requirements.
- We can also handle annual inspection and testing for the same system.
Learn more about commercial fire alarm monitoring.
FAQ
EST2 questions
Can Fireside monitor my Edwards / EST EST2?
In most cases, yes. We check the EST2's condition, programming access and reporting format on site, then recommend whether to keep it with a new communicator or replace it.
What happens to my EST2 when the phone line is removed?
The separate communicator that reports for the panel loses its line. We replace or reprogram that communicator to use cellular or IP.
What format does the EST2 report in?
Commonly documented options are Contact ID, SIA. The actual format depends on programming and any attached communicator, so we confirm it on site.
Model and format information comes from manufacturer documentation and field experience. Panel revisions, firmware, programming and attached communicators change what a specific system can do, so Fireside confirms every system on site before quoting. Fire alarm monitoring changes must meet NFPA 72 and local fire authority requirements.