San Francisco Pillow Test (SFFC 1103.7.6.1) — 75 dBA at every pillow. Deadline passed; fines are being issued.

Get compliant →

NAPCO Magnum and Gemini · Fire/Burglary

Magnum Alert series monitoring & upgrades

NAPCO's Magnum Alert panels came before the Gemini series. They are now uncommon but are still found in older commercial buildings.

At a glance

Panel details

Manufacturer
NAPCO Magnum and Gemini
Model
Magnum Alert series
Family
Magnum Alert
Panel type
Fire/Burglary
Communicator
Built-in dialer. Supported formats vary by model and EPROM revision.
Documented formats
Contact IDPulse formats

Technical notes

What to know about the Magnum Alert series

  • Model labels and EPROM revisions vary, so we read the board label on site.
  • Keypad and part availability is limited.

Why customers call

Common reasons for a monitoring upgrade

  • Failing keypads or board
  • Phone line removal
  • Takeover of a long-unmonitored system

Phone lines

Telephone line replacement

  • The Magnum Alert series's built-in dialer expects a phone line. When the carrier removes copper or moves the line to VoIP, signals can be delayed, partial or lost.
  • We test signals to the central station before and after the change, so you have a record that every alarm, trouble and supervisory signal arrives.
  • For fire alarm monitoring, the replacement path must meet NFPA 72 and the local fire authority's requirements. Some jurisdictions require a permit or acceptance test.

Cellular & IP

Monitoring options

  • Commonly documented formats for this model include Contact ID, Pulse formats. The format actually in use depends on programming, firmware and any attached communicator.
  • A universal cellular communicator that captures the dialer, or a manufacturer-native cellular/IP module, is usually the simplest option.
  • For fire signals, we use communicators listed for fire alarm service and dual-path (cellular plus IP) options where appropriate.

Takeover

Commercial monitoring takeover

  • We inspect the Magnum Alert series, confirm programming access and back up the existing settings where possible.
  • We move the account to Fireside's UL-Listed central station and set up your call list and dispatch instructions.
  • Every zone and trouble signal is tested end to end before we close out the job.

See fire alarm system takeover.

Fire alarm

Fire alarm monitoring

  • Alarm, supervisory and trouble signals are monitored 24/7 by a UL-Listed central station.
  • Replacement communicators are listed for fire alarm service and installed to meet NFPA 72 and local fire authority requirements.
  • We can also handle annual inspection and testing for the same system.

Learn more about commercial fire alarm monitoring.

FAQ

Magnum Alert series questions

Can Fireside monitor my NAPCO Magnum and Gemini Magnum Alert series?

In most cases, yes. We check the Magnum Alert series's condition, programming access and reporting format on site, then recommend whether to keep it with a new communicator or replace it.

What happens to my Magnum Alert series when the phone line is removed?

Its built-in dialer can't reach the central station, so signals stop or become unreliable. A cellular or IP communicator restores reporting.

What format does the Magnum Alert series report in?

Commonly documented options are Contact ID, Pulse formats. The actual format depends on programming and any attached communicator, so we confirm it on site.

Related

Other NAPCO Magnum and Gemini panels

Model and format information comes from manufacturer documentation and field experience. Panel revisions, firmware, programming and attached communicators change what a specific system can do, so Fireside confirms every system on site before quoting. Fire alarm monitoring changes must meet NFPA 72 and local fire authority requirements.