DMP (Digital Monitoring Products) · Fire/Burglary
DMP 1912 monitoring & upgrades
The DMP 1912 is an older commercial command processor for combined fire and burglary, common in banks and commercial buildings.
At a glance
Panel details
- Manufacturer
- DMP (Digital Monitoring Products)
- Model
- DMP 1912
- Family
- 1900-series
- Panel type
- Fire/Burglary
- Communicator
- Built-in dialer that reports in DMP's DD format to DMP-compatible receivers.
- Documented formats
- DMP DDPulse formats
Technical notes
What to know about the DMP 1912
- Current DMP communicators are designed for XR panels, so upgrading often means replacing the panel.
- Existing zone wiring and many devices can often be reused with a current XR panel.
Why customers call
Common reasons for a monitoring upgrade
- Copper line retirement
- Receiver support for older formats
- Planning a replacement
Phone lines
Telephone line replacement
- The DMP 1912's built-in dialer expects a phone line. When the carrier removes copper or moves the line to VoIP, signals can be delayed, partial or lost.
- We test signals to the central station before and after the change, so you have a record that every alarm, trouble and supervisory signal arrives.
- For fire alarm monitoring, the replacement path must meet NFPA 72 and the local fire authority's requirements. Some jurisdictions require a permit or acceptance test.
Cellular & IP
Monitoring options
- Commonly documented formats for this model include DMP DD, Pulse formats. The format actually in use depends on programming, firmware and any attached communicator.
- Because this panel may use a manufacturer-specific format, we usually prefer a manufacturer-compatible cellular or network path, or reprogramming to a format the new communicator supports.
- For fire signals, we use communicators listed for fire alarm service and dual-path (cellular plus IP) options where appropriate.
Takeover
Commercial monitoring takeover
- We inspect the DMP 1912, confirm programming access and back up the existing settings where possible.
- We move the account to Fireside's UL-Listed central station and set up your call list and dispatch instructions.
- Every zone and trouble signal is tested end to end before we close out the job.
Fire alarm
Fire alarm monitoring
- Alarm, supervisory and trouble signals are monitored 24/7 by a UL-Listed central station.
- Replacement communicators are listed for fire alarm service and installed to meet NFPA 72 and local fire authority requirements.
- We can also handle annual inspection and testing for the same system.
Learn more about commercial fire alarm monitoring.
FAQ
DMP 1912 questions
Can Fireside monitor my DMP (Digital Monitoring Products) DMP 1912?
In most cases, yes. We check the DMP 1912's condition, programming access and reporting format on site, then recommend whether to keep it with a new communicator or replace it.
What happens to my DMP 1912 when the phone line is removed?
Its built-in dialer can't reach the central station, so signals stop or become unreliable. A cellular or IP communicator restores reporting.
What format does the DMP 1912 report in?
Commonly documented options are DMP DD, Pulse formats. The actual format depends on programming and any attached communicator, so we confirm it on site.
Related
Other DMP (Digital Monitoring Products) panels
Model and format information comes from manufacturer documentation and field experience. Panel revisions, firmware, programming and attached communicators change what a specific system can do, so Fireside confirms every system on site before quoting. Fire alarm monitoring changes must meet NFPA 72 and local fire authority requirements.