San Francisco Pillow Test (SFFC 1103.7.6.1) — 75 dBA at every pillow. Deadline passed; fines are being issued.

Get compliant →

Fire Alarm

DMP XR-Series Combination Fire installation, service & monitoring

DMP XR-Series — combination commercial fire alarm and burglary from a single American-made platform.

Products

DMP XR-Series Combination Fire products we install

  • XR550 — 574-zone combination fire and burglary panel (UL 864 9th ed.)
  • XR150 — 194-zone combination commercial fire and burglary panel
  • 1100-Series 900 MHz two-way encrypted wireless smoke and heat detectors
  • 263C / 265C addressable and wireless zone expansion
  • 7800-Series LTE-M dual-SIM fire alarm communicator
  • SCS-1R IP + cellular receiver at our UL-Listed central station

Installation

DMP XR-Series Combination Fire installation

  • DMP XR-Series combo fire + burg deployments — UL 864 submittals, battery calcs, voltage-drop calcs, and AHJ acceptance testing coordinated in-house.
  • Riser diagrams, battery calcs, and voltage drop calcs stamped for AHJ submittal
  • Coordinated shop drawings integrated with sprinkler, elevator, and HVAC trades
  • Panel commissioning and full point-to-point test to sequence of operation
  • Acceptance test walkthrough with the AHJ on-site

Repair

DMP XR-Series Combination Fire repair & service

  • Same-day dispatch for panel troubles, ground faults, and open loops
  • Battery replacement, SLC device replacement, and NAC circuit repair
  • Voice-EVAC amplifier and speaker circuit troubleshooting
  • 5-year sensitivity testing and annual NFPA 72 inspection

Monitoring

DMP XR-Series Combination Fire monitoring

  • UL 864 Listed central-station signaling over dual-path IP + LTE-M
  • Priority handling for water flow, pull station, and general alarm
  • AHJ dispatch, tenant call list, and runner service
  • Monthly signal history and annual inspection reporting

Compatibility

Compatibility & integrations

  • UL 864 9th edition COMMERCIAL FIRE listing — approved for protected-premises fire alarm service
  • Combines fire and burglary in one enclosure with one keypad and one communicator
  • Native LTE-M signaling — no POTS lines required
  • Integrates with Entré access control and DMP video for unified life-safety and security
  • Contact ID and native SIA reporting to the SCS-1R receiver

FAQ

Frequently asked

Do you install new DMP XR-Series Combination Fire systems in California?

Yes. Fireside Security is a licensed C-10 contractor and an experienced DMP XR-Series Combination Fire integrator across California. We handle design, permit submittal, installation, commissioning, and acceptance testing.

Can you take over service on an existing DMP XR-Series Combination Fire system?

Yes. We routinely take over DMP XR-Series Combination Fire systems installed by other contractors. We start with a full site survey, verify programming, replace end-of-life components, and bring documentation current.

Do you monitor DMP XR-Series Combination Fire fire alarm panels at a UL-Listed central station?

Yes. All monitoring is delivered from a UL 864 Listed central station over dual-path IP + LTE-M cellular — no dependency on copper POTS lines being retired in 2026.

Ready to modernize your facility's life-safety infrastructure?

Talk to a licensed security specialist about your fire alarm, monitoring, POTS replacement, access, or video project. Same-day site surveys throughout California.