San Francisco Pillow Test (SFFC 1103.7.6.1) — 75 dBA at every pillow. Deadline passed; fines are being issued.

Get compliant →

Fire Alarm

Notifier installation, service & monitoring

Enterprise-grade addressable fire alarm for California's most demanding occupancies.

Products

Notifier products we install

  • NFS2-3030 large-scale addressable panel
  • NFS2-640 mid-size addressable panel
  • ONYX Series voice evacuation with digital audio
  • NOTI-FIRE-NET high-speed networked systems
  • FSB-200 addressable smoke detectors
  • FMM-4-20 addressable monitor modules
  • ONYXWorks central command graphics workstation

Installation

Notifier installation

  • We are experienced Notifier installers with technicians factory-trained on the NFS2 platform and ONYX voice systems. Every install includes stamped shop drawings, coordinated sequence of operation, and full battery calculations.
  • Riser diagrams, battery calcs, and voltage drop calcs stamped for AHJ submittal
  • Coordinated shop drawings integrated with sprinkler, elevator, and HVAC trades
  • Panel commissioning and full point-to-point test to sequence of operation
  • Acceptance test walkthrough with the AHJ on-site

Repair

Notifier repair & service

  • Same-day service on Notifier panel troubles, ground faults, SLC loop opens, and voice-EVAC amplifier failures. We stock common SLC devices, batteries, and amplifier boards for our maintained sites.
  • Same-day dispatch for panel troubles, ground faults, and open loops
  • Battery replacement, SLC device replacement, and NAC circuit repair
  • Voice-EVAC amplifier and speaker circuit troubleshooting
  • 5-year sensitivity testing and annual NFPA 72 inspection

Monitoring

Notifier monitoring

  • UL 864 Listed central-station signaling over dual-path IP + LTE-M
  • Priority handling for water flow, pull station, and general alarm
  • AHJ dispatch, tenant call list, and runner service
  • Monthly signal history and annual inspection reporting

Compatibility

Compatibility & integrations

  • SLC loop devices across the entire ONYX Series
  • BACnet and Modbus integration to building automation
  • Third-party voice-EVAC amplifiers via digital audio loop
  • Fire station alerting via IP or dry-contact bridge
  • UL 864 9th edition central-station monitoring over IP + LTE-M

FAQ

Frequently asked

Do you install new Notifier systems in California?

Yes. Fireside Security is a licensed C-10 contractor and an experienced Notifier integrator across California. We handle design, permit submittal, installation, commissioning, and acceptance testing.

Can you take over service on an existing Notifier system?

Yes. We routinely take over Notifier systems installed by other contractors. We start with a full site survey, verify programming, replace end-of-life components, and bring documentation current.

Do you monitor Notifier fire alarm panels at a UL-Listed central station?

Yes. All monitoring is delivered from a UL 864 Listed central station over dual-path IP + LTE-M cellular — no dependency on copper POTS lines being retired in 2026.

Ready to modernize your facility's life-safety infrastructure?

Talk to a licensed security specialist about your fire alarm, monitoring, POTS replacement, access, or video project. Same-day site surveys throughout California.