Fire Alarm
Silent Knight installation, service & monitoring
Silent Knight addressable and combination panels for small-to-mid commercial.
Products
Silent Knight products we install
- IntelliKnight 5820XL addressable panel
- 6820EVS voice evacuation panel
- 5860 remote annunciator
- SD505 addressable smoke and heat detectors
- SK-5217 dual-line communicator
Installation
Silent Knight installation
- Riser diagrams, battery calcs, and voltage drop calcs stamped for AHJ submittal
- Coordinated shop drawings integrated with sprinkler, elevator, and HVAC trades
- Panel commissioning and full point-to-point test to sequence of operation
- Acceptance test walkthrough with the AHJ on-site
Repair
Silent Knight repair & service
- Same-day dispatch for panel troubles, ground faults, and open loops
- Battery replacement, SLC device replacement, and NAC circuit repair
- Voice-EVAC amplifier and speaker circuit troubleshooting
- 5-year sensitivity testing and annual NFPA 72 inspection
Monitoring
Silent Knight monitoring
- UL 864 Listed central-station signaling over dual-path IP + LTE-M
- Priority handling for water flow, pull station, and general alarm
- AHJ dispatch, tenant call list, and runner service
- Monthly signal history and annual inspection reporting
Compatibility
Compatibility & integrations
- SD505 device compatibility with select Farenhyt and Fire-Lite lines
- Voice-EVAC integration with 6820EVS audio
- Cellular signaling via SK-Cell and Uplink communicators
FAQ
Frequently asked
Do you install new Silent Knight systems in California?
Yes. Fireside Security is a licensed C-10 contractor and an experienced Silent Knight integrator across California. We handle design, permit submittal, installation, commissioning, and acceptance testing.
Can you take over service on an existing Silent Knight system?
Yes. We routinely take over Silent Knight systems installed by other contractors. We start with a full site survey, verify programming, replace end-of-life components, and bring documentation current.
Do you monitor Silent Knight fire alarm panels at a UL-Listed central station?
Yes. All monitoring is delivered from a UL 864 Listed central station over dual-path IP + LTE-M cellular — no dependency on copper POTS lines being retired in 2026.
Other fire alarm platforms
Ready to modernize your facility's life-safety infrastructure?