San Francisco Pillow Test (SFFC 1103.7.6.1) — 75 dBA at every pillow. Deadline passed; fines are being issued.

Get compliant →

Radionics / Bosch · Intrusion

D4112 / D6112 monitoring & upgrades

The Radionics D4112 and D6112 are early, small command centers still found in some older buildings.

At a glance

Panel details

Manufacturer
Radionics / Bosch
Model
D4112 / D6112
Family
D4000 / D6000
Panel type
Intrusion
Communicator
Built-in dialer with older Radionics formats.
Documented formats
BFSKPulse formats

Technical notes

What to know about the D4112 / D6112

  • BFSK and pulse-only reporting give very little detail. Replacement is usually the best path.

Why customers call

Common reasons for a monitoring upgrade

  • Limited reporting detail
  • Panel age

Phone lines

Telephone line replacement

  • The D4112 / D6112's built-in dialer expects a phone line. When the carrier removes copper or moves the line to VoIP, signals can be delayed, partial or lost.
  • We test signals to the central station before and after the change, so you have a record that every alarm, trouble and supervisory signal arrives.

Cellular & IP

Monitoring options

  • Commonly documented formats for this model include BFSK, Pulse formats. The format actually in use depends on programming, firmware and any attached communicator.
  • Because this panel may use a manufacturer-specific format, we usually prefer a manufacturer-compatible cellular or network path, or reprogramming to a format the new communicator supports.
  • For intrusion, cellular with IP backup keeps alarms flowing if one path goes down.

Takeover

Commercial monitoring takeover

  • We inspect the D4112 / D6112, confirm programming access and back up the existing settings where possible.
  • We move the account to Fireside's UL-Listed central station and set up your call list and dispatch instructions.
  • Every zone and trouble signal is tested end to end before we close out the job.

See commercial intrusion monitoring.

FAQ

D4112 / D6112 questions

Can Fireside monitor my Radionics / Bosch D4112 / D6112?

In most cases, yes. We check the D4112 / D6112's condition, programming access and reporting format on site, then recommend whether to keep it with a new communicator or replace it.

What happens to my D4112 / D6112 when the phone line is removed?

Its built-in dialer can't reach the central station, so signals stop or become unreliable. A cellular or IP communicator restores reporting.

What format does the D4112 / D6112 report in?

Commonly documented options are BFSK, Pulse formats. The actual format depends on programming and any attached communicator, so we confirm it on site.

Model and format information comes from manufacturer documentation and field experience. Panel revisions, firmware, programming and attached communicators change what a specific system can do, so Fireside confirms every system on site before quoting. Fire alarm monitoring changes must meet NFPA 72 and local fire authority requirements.